U500 is a proposed spectral metric for outdoor lighting that expresses the percentage of a light source’s visible radiant energy at wavelengths below approximately 500 nanometers—the blue/violet portion of its output. The aim is to specify short-wavelength content directly, rather than rely on correlated color temperature (CCT) as a proxy. The Czech Lighting Society describes the method in a September 2024 white paper.
How it is calculated
The white paper defines it as the short-wavelength energy from 380–500 nm divided by the total visible energy from 380–780 nm, expressed as a percentage:
Here, E(λ) represents the source’s measured spectral distribution. A U500 of 5% means that 5% of its visible radiant energy falls in the 380–500 nm band. This is an energy ratio—not a percentage of lumens, which would incorporate the eye’s wavelength-dependent sensitivity.
What is being proposed for outdoor lighting?
In a recent public proposal, Hynek Medřický calls for U500 below 5% for nighttime outdoor lighting, alongside strict controls on illuminance, glare, and spill light. That is a proposed performance target, not a concensus adopted requirement.
Other work discusses different limits according to location. A paper on sustainable architectural lighting describes a Czech environmental methodology being finalized with maximum U500 values ranging from 12% in city centers to 1% in protected natural areas. Those are context-specific proposed limits, rather than an inherent part of the metric’s definition.
Why it matters—and its limits
The rationale is to quantify the short-wavelength component as a way to address light pollution and biological disturbance. The white paper presents U500 as a deliberately simple measure of that component; Czech research also uses it to characterize potential effects on living organisms.
One should keep in mind that U500 describes spectral composition, not the entire outdoor-lighting installation. A low value does not by itself establish that a site has appropriate light levels, low glare, or little spill light—which is why the proposal pairs the spectral limitation with those separate controls. Nor should the percentage be interpreted as a universal biological-risk score: it is simply a ratio of energy in two wavelength bands.
Top image: Spectral measurements by Radim Václavíček. Source.






![2610_LightNow_Archlight_Banner Ad_900x400 | LightNOW Dallas Market Center ArcLight Summit banner: Call for Speakers, June 22–23, 2027 — Apply Now (logo with colorful arc.”] ,](https://i0.wp.com/www.lightnowblog.com/wp-content/uploads/2026/10/2610_LightNow_Archlight_Banner-Ad_900x400-e1792264459229.png?fit=900%2C400&ssl=1)