In this project, 32 halogen track luminaires used to light an enclosed gallery exhibit were replaced with an LED system using 26 track fixtures. Key findings include:
* The LED system resulted in 63 percent energy savings compared to the halogen system and produced comparable illuminance on the lighted artifacts.
* The simple payback for the overall LED system compared to the halogen system was roughly 3 years. Comparing the LED luminaires one-for-one against the halogen luminaires, however, resulted in paybacks ranging from 5 to 11 years, owing to factors in this museum application such as equipment used to filter the light, maintenance costs, and the effect of the lighting system on the air-conditioning system.
* Because the LED luminaires used do not emit energy in the infrared or ultraviolet regions of the electromagnetic spectrum, they are expected to be less detrimental to some museum artifacts.
Click here to download the report.




![2610_LightNow_Archlight_Banner Ad_900x400 | LightNOW Dallas Market Center ArcLight Summit banner: Call for Speakers, June 22–23, 2027 — Apply Now (logo with colorful arc.”] ,](https://i0.wp.com/www.lightnowblog.com/wp-content/uploads/2026/10/2610_LightNow_Archlight_Banner-Ad_900x400-e1792264459229.png?fit=900%2C400&ssl=1)